Single Core Nyvin Cables and PVC Insulated Uninyvin Electric Cable manufacturer in India
Ever wondered what types of cables are used in huge machines like aircraft that fly in the air? Uninyvin Cableis the single-core, annealed tinned copper conductors that are used in these huge machines. They display resistance to heat up to 105 degrees C and have an ambient temperature of -30 degrees C to +65 degrees C. Apart from being used in aircraft Uninyvin Cable manufacturers recommend these cables to be used in UPS battery cables, UPS wires, panel board wiring, interconnection wires and so on. They display excellent resistance to moisture and abrasion along with resistance towards fuel, oils, and alkalis.
Unlike PVC cables these Uninyvin Cables have 3 layers of insulation. First, the copper conductor is plated with tin followed by PVC insulation, and last but not least it is covered with fiberglass yarn braiding. The tin plating prevents it from oxidizing and makes it solderable whereas the fiberglass yarn braiding increases the Uninyvin Electric Cables'resistance to fire and flames. Nylon braiding is used to cover the fiberglass braid which is then lacquered with a nylon varnish coat. One of the benefits of using these cables is that Uninyvin Power Cable does not overheat even after continuous work. The heat released by it is also not dissipated in the surrounding. While maintaining a constant voltage prevents the entire system from overheating. These Nyvin Cables have a high current carrying capacity as compared to the PVC wires.
U-6, 115A Uninyvin Cable produced by us is 3 times lighter as compared to PVC cables. As they display flexibility they are easy to install in all sorts of spaces. Under fluctuating voltage as well these cables display excellent performance without causing error or breaking down. PVC Insulated Uninyvin Cables have multicore and heavy-duty structure due to which they are used in the telecommunication industry as ground cables. Since they are made up of copper conductors they are said to be cost-effective. We have been producing these Uninyvin Interlinks for Batteries and many other applications. The quality of our product and pocket friendly prices have made us one of the most relied upon and trusted Uninyvin Cable manufacturersin India.
Supplier & exporter of Uninyvin Power Cable with Annealed Tinned Copper Conductor
Uninyvin Cables Specification Chart
| Cables range | 20GA, 16GA, 18GA, 14GA, 8GA, 2GA, 6GA, 0GA, 12GA, 4GA, 15GA, 10GA |
| Extreme temperature range |
-40 to 105 C |
| Material | glossy material Tinned, Environmentally friendly, Silver or Nickel plated copper etc. |
| Conductor | Stranded 99.99% oxygen free copper and tin plated copper, copper coated al |
| Cables Colour | As per customer requirement |
| Packing | carton packing, pallet packing , wooden / plastic reels |
| Export To | Sri lanka, Nigeria, Myanmar, Indonesia, Qatar, Bahrain, Zambia, Belgium, Chile, Italy, Bhutan, Nepal, Israel, United Kingdom, Cuba, Malawi, Mozambique, Netherlands, Qatar, Bangladesh, Germany, Singapore, Kenya, Brazil, Poland, Tanzania, Kuwait, Oman, Russia, United Arab Emirates, Egypt, Bhutan, Oman, Colombia, Australia, Malaysia, Saudi Arabia, Nepal, Iraq, Argentina, Morocco, Philippines, Sudan, United States, Austria, South Africa |
Manufacturer & Exporter of PVC Insulated Uninyvin Cables for server rooms and UPS systems
Price list of Nyvin Cables
| Description | Price Per Meter in USD |
| Uninyvin Cables cutting and stripping machine Motor Cables | US $ 0.20 - 1.00 |
| Uninyvin Cables Cutting Stripping Machine For Heater Cables | US $ 1.00 |
| Uninyvin Cables 2 X M4 Ring Earth Wire | US $ 0.40 |
| Mirracle Nyvin Uninyvin Cables Code 4 | US $ 2.95 |
what is Uninyvin Cables?
Nyvin Cables with an Annealed Tinned Copper channel and a protection of HR PVC Compound, Glass Braid, Nylon Braid and defensive nylon lacquering for sizes going from 10 to 0000. Nyvinal. Like the Nyvin range yet with a conduit of aluminum rather than copper.
Uninyvin Electric Cables application
These cables are utilized in UPS frameworks and worker rooms as the nylon and fiber glass plait on the cables doesn't permits the heat generated in the conductor, because of consistent activity, to be felt in the encompassing regions. These cables are generally utilized in airplane cabling.
Nyvin Cables Construction
- Conductor = Annealed tinned copper to IS 10241 Part 3, uniformly bunched to form a circular shape
- Lacquer = Overall construction is finally lacquered with nylon varnish
- Insulation = Special core insulation HR-PVC 105° C
- Secondary Braid = Braided with nylon fiber, 100% coverage
- Primary Braid = Braided with glass fiber, 100% coverage
Properties of Uninyvin Power Cables
- Operating Temperature Range : -35°C to 105°C
- Max. Operating Voltage : 600V r.m.s.
- Resistant to ester based fluids, acids, chemicals and solvents. The nylon and glass fibers are very good heat resistant materials.
Size chart of PVC Insulated Uninyvin Cables
| Cables Size | Conductor | Radial Thickness | Nylon Braidand Lacquer | Overall Diameter of Cables | DC Conductor Resistance at 20°C (Ω/km) |
Max. Current Rating (Amps.) – BS G 177 | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Nom.Cross Sectional Area (Sq. mm) |
No. & Dia.of Wiresin (mm) | Max. Conductor Diameter (mm) |
Min. Conductor Diameter (mm) |
Min. PVC Insulation |
Max.(mm) | Min.(mm) | Max.(mm) | Min.(mm) | |||
| 14 | 2.05 | 70/0.193 | 1.956 | 1.803 | 0.279 | 0.178 | 0.076 | 3.4 | 3 | 9.2 | 31 |
| 12 | 3.22 | 110/0.191 | 2.438 | 2.286 | 0.279 | 0.178 | 0.076 | 3.8 | 3.5 | 5.85 | 43 |
| 10 | 5.33 | 73/0.305 | 3.15 | 2.896 | 0.381 | 0.381 | 0.127 | 5 4. | 6 | 3.532 | 61 |
| 8 | 8.76 | 120/0.305 | 3.242 | 3.937 | 0.381 | 0.381 | 0.127 | 6.3 | 5.9 | 2.154 | 87 |
| 6 | 13.3 | 182/0.305 | 5.537 | 5.08 | 0.381 | 0.381 | 0.127 | 7.6 | 7.3 | 1.422 | 115 |
| 4 | 21.5 | 294/0.305 | 6.909 | 6.452 | 0.483 | 0.381 | 0.127 | 9.3 | 8.8 | 0.877 | 160 |
| 2 | 33.3 | 203/0.457 | 8.763 | 8.128 | 0.483 | 0.381 | 0.127 | 11.0 | 10.5 | 0.565 | 200 |
| 1 | 40.7 | 248/0.457 | 9.754 | 9.119 | 0.559 | 0.381 | 0.127 | 12.2 | 11.7 | 0.463 | 220 |
| 0 | 53.0 | 323/0.457 | 10.973 | 10.338 | 0.635 | 0.381 | 0.127 | 13.7 | 13.0 | 0.355 | 240 |
| 00 | 68.3 | 416/0.457 | 12.446 | 11.684 | 0.686 | 0.381 | 0.127 | 15.4 | 14.6 | 0.276 | 270 |
U-6, 115A Uninyvin Cables Sizes
| Cables Size | Nominal Cross Sectional Area (Sq. mm) | Max. Current Rating (Amps) | |||
|---|---|---|---|---|---|
| Single Cables | 3 – Bunched Cables | 7 – Bunched Cables | 12 – Bunched Cables | ||
| 14 | 2.05 | 31 | 24 | 17 | 12 |
| 12 | 3.22 | 43 | 30 | 22 | 15 |
| 10 | 5.33 | 61 | 47 | 36 | 25 |
| 8 | 8.76 | 87 | 65 | 49 | 36 |
| 6 | 13.3 | 115 | 87 | 65 | – |
| 4 | 21.5 | 160 | 120 | 92 | – |
| 2 | 33.3 | 200 | 155 | 120 | – |
| 1 | 40.7 | 220 | 165 | 130 | – |
| 0 | 53 | 240 | 185 | 168* | – |
| 00 | 68.3 | 270 | 210/240* | 190** | – |
Locate our Stockist and Distributors in neighborhood countries

Mining Industry
Uninyvin Cables cutting and stripping machine Motor Cables
Morocco, Saudi Arabia, Iraq, Oman, Bangladesh, Bhutan, Australia, Mozambique, Kenya, Colombia

Automobiles Industry
Uninyvin Cables Cutting Stripping Machine For Heater Cables
Nepal, Chile, Tanzania, Malawi, Oman, Bhutan, Germany, Italy, South Africa, Brazil, Singapore

Aerospace Industry
Mirracle Nyvin Uninyvin Cables Code 4
Austria, Argentina, Zambia, Nepal, Indonesia, Qatar, Poland, Russia, Belgium, Malaysia, Qatar,
Ambient Temperature of Uninyvin Cables
| Ambient temp. (°C) | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 | 100 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Derating factor | 1.0 | 0.96 | 0.92 | 0.88 | 0.83 | 0.78 | 0.75 | 0.73 | 0.68 | 0.62 | 0.53 | 0.48 | 0.3 |
Uninyvin Power Cables Current Ratings
| Cables Size | Nominal Cross Sectional Area (Sq. mm) | Max. Current Rating (Amps) | |||
|---|---|---|---|---|---|
| Single Cables | 3 – Bunched Cables | 7 – Bunched Cables | 12 – Bunched Cables | ||
| 14 | 2.05 | 50 | 47 | 43 | 42 |
| 12 | 3.22 | 72 | 67 | 62 | 60 |
| 10 | 5.33 | 110 | 107 | 104 | 101 |
| 8 | 8.76 | 173 | 165 | 159 | 153 |
| 6 | 13.3 | 250 | 236 | 230 | – |
| 4 | 21.5 | 390 | 378 | 360 | – |
| 2 | 33.3 | 545 | 530 | 520 | – |
| 1 | 40.7 | 620 | 600 | 590 | – |
| 0 | 53 | 705 | 690 | 680 | – |
| 00 | 68.3 | 820 | 810 | 800 | – |
Uninyvin Electric Cables Testing
| Sr. No. | Fluid Represented | Test Fluids | Temp. of Test | Max. Change in Dia. % |
|---|---|---|---|---|
| 1 | Aviation Turbine Fuel | Kerosene | 20 ± 0.5 | 5 |
| 2 | Fuel | 70% ISO Octane 30% Toluene by Vol. | 20 ± 0.5 | 5 |
| 3 | Hydraulic | Fluid 80% Ethylene Glycol Mono Ethyl Ether, 20% Castor Oil by Vol. | 50 ± 2 | 5 |
| 4 | Ester Based Lubricating Oil | Ester Based Hydraulic Fluid | 100 ± 2 | 5 |
Uninyvin Vs Normal Cables
| Elements | Uninyvin | Normal |
| Heat Resistance | High | Low |
| Material Weight | Low | High |
| Abrasive Strength | Good | Nil |
| Heat Emission | Nil | High |
| High Temperature | 105 C | 70 C |
| Low Temperature | -35 C | -20 C |
| Investment | Low | High |
| Conductor Area | Low | High |
| Cost Factor | Low | High |
| Mechanical Strength | Good | Average / Poor |
11amps to 350amps Current Rating U-6, 115A Uninyvin Cable supplier & exporter in Mumbai
Uninyvin cable vs pvc cables
Uninyvin cables has a lot higher current conveying limit than the customary PVC wires. To give you a model, where a 120 mm2 customary PVC cable conveys 235 Amps of current, a 50mm2 Uninyvin cables can convey 240 Amps. Uninyvin wires are fit for turning out easily for voltages up to 600/1100 V r.m.s. at frequencies of 1600 c/s.
Dimension of Uninyvin Cables
| Cables Size | Conductor Nominal Area | Diameter | Overall diameter of finished cable | Maximum conductor Resistance for 900 mtr at 20° c | Current Rating Amps |
| 22 | 0.347 | 0.838 | 1.8 | 49.66 | 14 |
| 14 | 2.05 | 1.95 | 3 | 8.41 | 40 |
| 18 | 0.966 | 1.32 | 2.3 | 17.82 | 23 |
| 20 | 0.556 | 1.04 | 2.0 | 30.95 | 18 |
| 6 | 13.3 | 5.54 | 7.3 | 1.3 | 148 |
| 10 | 5.33 | 3.15 | 4.6 | 3.23 | 78 |
| 2 | 33.3 | 8.76 | 10.5 | 0.517 | 256 |
| 16 | 1.17 | 1.55 | 2.5 | 14.17 | 27 |
| 12 | 3.22 | 2.43 | 3.5 | 5.35 | 55 |
| 000 | 84.2 | 13.91 | 16.1 | 0.204 | 384 |
| 8 | 8.76 | 4.25 | 5.9 | 1.97 | 111 |
| 4 | 21.5 | 6.90 | 8.8 | 0.802 | 205 |
| 0 | 53 | 10.97 | 13.0 | 0.325 | 308 |
| 1 | 40.7 | 9.75 | 11.7 | 0.423 | 282 |
| 00 | 68.3 | 12.44 | 14.6 | 0.252 | 346 |
| 0000 | 109 | 15.62 | 17.9 | 0.158 | 450 |
Weight of Nyvin Cables
| Uninyvin Cables | Size(area) | Conductor Diameter “Max” | Overall Diameter “Max” | Conductor Resistance at 20°C “Max” |
Max Current Rating “Amps” |
| Core | “Sq. mm” | “mm” | “mm” | “ Ω/ 900m” | BS-G-177 |
| 22 | 0.347 | 0.838 | 2.00 | 49.660 | 11 |
| 20 | 0.566 | 1.04 | 2.30 | 30.950 | 14 |
| 18 | 0.966 | 1.32 | 2.50 | 17.820 | 18 |
| 16 | 1.17 | 1.55 | 2.80 | 14.700 | 21 |
| 14 | 2.05 | 1.95 | 3.40 | 8.410 | 31 |
| 12 | 3.22 | 2.43 | 3.80 | 5.350 | 43 |
| 10 | 5.33 | 3.15 | 5.00 | 3.230 | 61 |
| 8 | 8.76 | 4.24 | 6.30 | 1.970 | 87 |
| 6 | 13.3 | 5.54 | 7.50 | 1.300 | 115 |
| 4 | 21.5 | 6.90 | 9.30 | 0.802 | 160 |
| 2 | 33.3 | 8.76 | 11.00 | 0.517 | 200 |
| 1 | 40.7 | 9.75 | 12.20 | 0.423 | 220 |
| 0 | 53.0 | 11.0 | 13.70 | 0.325 | 240 |
| 00 | 68.3 | 12.4 | 15.40 | 0.252 | 270 |
| 000 | 84.2 | 13.9 | 16.90 | 0.204 | 300 |
| 0000 | 109 | 15.6 | 18.70 | 0.158 | 350 |
Uninyvin Cables Features
- Light weight
- Safe and secure
- Reliable and efficient
- Chloroprene Cables are Easy to carry
- Easy to implement in the circuits
- Uninyvin Cables may be used in dry, damp, or wet locations
- Widely used to distribute low voltage data/ signal
- These Uninyvin Cables can carry signals up to 40 volts
- Uninyvin Cables are suitable for electrical installation industrial control circuits for sending electrical signals
- Choice of conductors, screens and jacket materials to suit the most demanding applications.
- Jacket material options to provide high flexibility and excellent mechanical protection.
- Designed for stripping and overmolding.
- Choice of Uninyvin Cables dimensions
- Screening options that include bare copper braid, braid with drainwire, optimized braids with superior surface transfer impedance characteristics, and aluminum foil with drainwire.
Benefits of Uninyvin Power Cables
- Cost effectiveness
- Better temperature resistance then ordinary PVC cable
- Oil and water resistance
- Abrasion resistance
- High current caning capacity
Characteristics of U-6, 115A Uninyvin Cables
- Uninyvin cables have a much higher current carrying capacity than traditional PVC wires.
- These cables are used in battery circuitry where chemical exposure is high.
Uninyvin Cables HSN Code
| HSN Code | Description |
|---|---|
| 85444930 | Uninyvin Cables |
Many distributors, stockholders, stockists, suppliers, dealers, importers, exporters procure Uninyvin Interlinks for Batteries from Bhuwal Insulation and resale with higher margins, so buy Uninyvin Cable directly from Bhuwal and save your cost.
Uninyvin Interlinks for Batteries Technical Data
- Volts/Temperature: 600V, 2210F(1050 C)
- Insulation: PVC Insulation Chemical, flame, and moisture resistant
- Conductor : Solid /Stranded, Tinned Copper, Bare Copper
- Applications : Used as internal wiring for appliances and electronic equipment









Table of Content