600V UL 5335 Mica Fiber Glass Wire and Mica-Insulated Electric Cables manufacturer in India
Cables and wires are insulated with various materials to protect them from weather and other hazardous effects which might further lead to damages. One such type is the Mica Insulated Cable. It not only provides insulation against the electric current but also acts as a barrier between the wire and fire along with reducing the volume of toxic gases. Since mica as an element is non-toxic, halogen free and chemically neutral. The cable produced using this material is also non-adhesive, impregnated, and flexible.
Mica Insulated Cable is reinforced with the support of a polyethylene film and has a high-performance heat-resistant silicone resin. These cables can also resist water, acids, and alkalis. Furthermore, they also display resistance to vibration and shocks. They are resistant to radiation upto 109 rad. It belongs to the instrumental, control, and power cable family. Mica Insulated Wire is used in smoke extractors, lift, signal equipment, emergency lightings, telephoners, IT centers, emergency pumps, and so on. Moreover, they are also used in high apartments, cables, hospitals, airports, hotels, and cinema halls. They do not weaken with age and thus have a long life. Mica-insulated electric cables can withstand current loans and substantial stress without leading to an electrical failure. The need for a separate circuit protective conductor is eliminated due to the copper sheath. Since they are fully annealed they display good ductility. They also have a smaller diameter as compared to other soft skinned fire resistant wires.
We have been manufacturing these cables using high quality raw material that has been procured from trusted sources. We have been crowned as one of the most reliable and trusted Mica Insulated Cable manufacturers in India by our customers due to the quality of product and affordable prices. Our team of expertspasses these cables through various tests post the final finish is done to confirm their properties.
Manufacturer & Exporter of Mica Insulated Wire and UL 5107 Mica Glass Wire as per NF F 16101 standard
Mica Insulated Wire Price List
| Description | Price Per Meter in USD |
| Mica Insulated Stainless Steel Shield Cable For Household Heater | US $ 0.05 - 2.50 |
| Low Voltage Electric 0.6/1kv Mica Insulated Steel Wire Armored 4x150mm2 Cable | US $ 2.90 |
| 500C Copper Wire Mica Glass High Temperature Lead Wire Fire resistant Cable | US $ 0.15 - 14.00 |
| 500 degree copper Glass fiber insulated fire resistant mica high temperature cable | US $ 0.50 |
| High temperature wires mica insulated cable UL5128 | US $ 0.75 |
Mica glass insulated wire and UL 5335/5107 MG Wire supplier & exporter in India
Standard Specification Of Mica Insulated Cables
| Cables range | 20GA, 16GA, 18GA, 14GA, 8GA, 2GA, 6GA, 0GA, 12GA, 4GA, 15GA, 10GA |
| Extreme temperature range |
-40 to 105 C |
| Material | glossy material Tinned, Environmentally friendly, Silver or Nickel plated copper etc. |
| Conductor | Stranded 99.99% oxygen free copper and tin plated copper, copper coated al |
| Cables Colour | As per customer requirement |
| Packing | carton packing, pallet packing , wooden / plastic reels |
| Export To | Poland, Sri lanka, Chile, Malaysia, Bangladesh, Morocco, Zambia, Nigeria, Australia, United States, United Kingdom, Oman, Oman, Qatar, Argentina, Bhutan, Brazil, Russia, Singapore, Italy, Mozambique, Qatar, Malawi, Kuwait, Philippines, Saudi Arabia, Nepal, Bhutan, Iraq, South Africa, Kenya, Myanmar, Egypt, Colombia, Bahrain, Cuba, Germany, Austria, United Arab Emirates, Israel, Tanzania, Nepal, Sudan, Belgium, Indonesia, Netherlands |
What is Mica Insulated Cables?
Mica Insulated Cable is utilized in a scope of items on account of its extraordinary properties as a separator and dielectric. Mica Insulated Cable can uphold an electrostatic field while consuming insignificant warmth energy. It very well may be parted between 0.025mm to 0.125mm without losings its electrical properties and opposes crown release
UL 5335 Mica Fiber Glass Wire application
- Fire Control
- Railway Stations
- Communications
- Entertainment Venues
- Subways
- Airports
- High-rise Building
- Hospitals
- Shopping Malls
- Residence
- Chemical Industry
- Smelting
- Coal Mining
- Mining
Specification Sheet of UL 5107 Mica Glass Wire
| Cross section | Number and Diameter | Overall Diameter | DC Current resistance 20℃ | DC Current resistance 20℃ |
| 0.75 | 11 * 0.30 | 2.7 | 26.7 | 106.7 |
| 0.50 | 7 * 0.30 | 2.6 | 40.1 | 160.0 |
| 1.5 | 21 * 0.30 | 3 | 13.7 | 53.3 |
| 1.00 | 14 * 0.30 | 2.8 | 20 | 80.0 |
| 2.5 | 35 * 0.30 | 3.6 | 8.21 | 32.0 |
| 2.0 | 28 * 0.30 | 3.3 | 9.84 | 40.0 |
| 6.0 | 84 * 0.30 | 5.5 | 3.39 | 13.3 |
| 4.0 | 56 * 0.30 | 4.5 | 5.09 | 20.0 |
| 16 | 126 * 0.40 | 7.8 | 1.24 | 5.0 |
| 10 | 84 x0.40 | 6.6 | 1.95 | 8.0 |
| 35 | 276 * 0.40 | 11.2 | 0.548 | 2.3 |
| 25 | 196 * 0.40 | 9.5 | 0.79 | 3.2 |
| 95 | 475 * 0.50 | 17.4 | 0.205 | 0.8 |
| 70 | 360 * 0.50 | 15.4 | 0.289 | 1.1 |
| 50 | 396 * 0.40 | 13.2 | 0.384 | 1.6 |
| 120 | 616 * 0.50 | 20 | 0.162 | 0.7 |
Characteristic of Mica Glass Cables
- High and low temperature resistant
- acid-proof
- anti-aging
- grease-proofness
- alkali-resisting
- resistance to burning
- mould proof and excellent limpness
- weather ability
- electrical insulation property
UL 5107 Wire Standards
- UL Listed for 450°C with a 538°C maximum
- UL requirements for AWM Style 5107/5335
Sizes of UL 5335/5107 MG Wire
| Size | Conductor | Insulation Thickness | Braid Thickness | Diameter |
| 10 | 103/0.254 | 0.51 | 0.38 | 5.1±0.2 |
| 8 | 163/0.254 | 6.0±0.2 | ||
| 6 | 260/0.254 | 7.1±0.2 | ||
| 4 | 413/0.254 | 8.4±0.2 | ||
| 24 | 7/0.2 | 0.38 | 0.18 | 1.8±0.1 |
| 22 | 7/0.254 | 2.0±01 | ||
| 20 | 10/0.254 | 2.1±0.1 | ||
| 18 | 16/0.254 | 2.4±0.1 | ||
| 16 | 26/0.254 | 2.7±0.1 | ||
| 14 | 41/0.254 | 3.1±0.1 | ||
| 12 | 65/0.254 | 3.6±0.1 |
Check our material dispatch in following industries

Mining Industry
Mica Insulated Stainless Steel Shield Cable For Household Heater
Poland, Sri lanka, Chile, Malaysia, Bangladesh, Morocco, Zambia, Nigeria, Australia, United States

Automobiles Industry
500C Copper Wire Mica Glass High Temperature Lead Wire Fire resistant Cable
Oman, Oman, Qatar, Argentina, Bhutan, Brazil, Russia, Singapore, Italy, Mozambique, Qatar, Malawi

Aerospace Industry
Low Voltage Electric 0.6/1kv Mica Insulated Steel Wire Armored 4x150mm2 Cable
Kuwait, Philippines, Saudi Arabia, Nepal, Bhutan, Iraq, South Africa, Kenya, Myanmar, Egypt, Colombia
MG UL 5335/5107 High Temperature Wire Size chart
| Size | Conductor | Insulation Thickness | Braid Thickness | Diameter |
| 24 | 7/0.2 | 0.61 | 0.2 | 2.3±0.2 |
| 22 | 7/0.254 | 2.5±0.2 | ||
| 20 | 10/0.254 | 2.6±0.2 | ||
| 18 | 16/0.254 | 2.9±0.2 | ||
| 16 | 26/0.254 | 3.2±0.3 | ||
| 14 | 41/0.254 | 3.6±0.3 | ||
| 12 | 65/0.254 | 4.1±0.3 | ||
| 10 | 103/0.254 | 0.89 | 0.25 | 5.6±0.5 |
| 8 | 163/0.254 | 6.5±0.5 | ||
| 6 | 260/0.254 | 7.6±0.5 | ||
| 4 | 413/0.254 | 8.9±0.5 | ||
| 2 | 168/0.5 | 1.4 | 0.38 | 11.8±0.8 |
| 1 | 212/0.5 | 12.8±0.8 | ||
| 1/0 | 268/0.5 | 13.9±0.8 | ||
| 2/0 | 342/0.5 | 15.3±0.8 | ||
| 3/0 | 430/0.5 | 16.7±0.8 | ||
| 4/0 | 538/0.5 | 18.3±0.8 | ||
| 250kcmil | 633/0.5 | 1.52 | 19.7±0.8 | |
| 300kcmil | 760/0.5 | 21.3±1.0 | ||
| 350kcmil | 886/0.5 | 22.7±1.0 | ||
| 400kcmil | 396/0.8 | 24.0±1.0 | ||
| 500kcmil | 495/0.8 | 26.4±1.0 |
Construction of Mica-insulated electric cables
- Conductors = Nickel-Plated Copper channels work on the link's capacity to withstand mechanical harm and make it impervious to consumption
- Insulation = An imaginative Mica glass composite protection has a predictable quality.
- Jacket = This high temp wire has a fiberglass twist coat with an extra layer of clinical silicone that assists with settling the normal issue of dermatitis when working with fiberglass and plait brawl.
4AWG-26AWG MG UL 5335/5107 High Temperature Wire and Mica glass cable manufacturer & supplier in Mumbai
Mica Insulated Cable Structure
450C 600V UL5359 Mica Fiberglass Wire Dimension
| Size | Conductor Structure | Insulation Thickness | Braid Thickness | Diameter |
| 26 | 7/0.16 | 0.41 | 0.18 | 1.8±0.1 |
| 24 | 7/0.2 | 1.9±0.1 | ||
| 22 | 7/0.254 | 2.1±0.2 | ||
| 20 | 10/0.254 | 2.2±0.2 | ||
| 18 | 16/0.254 | 2.5±0.2 | ||
| 16 | 26/0.254 | 2.8±0.2 | ||
| 14 | 41/0.254 | 3.2±0.3 | ||
| 12 | 65/0.254 | 3.6±0.3 | ||
| 2 | 168/0.5 | 0.64 | 0.51 | 10.5±0.8 |
| 1 | 212/0.5 | 11.5±0.8 | ||
| 1/0 | 268/0.5 | 12.7±0.8 | ||
| 2/0 | 342/0.5 | 14.0±0.8 | ||
| 3/0 | 430/0.5 | 15.4±0.8 | ||
| 4/0 | 538/0.5 | 17.0±0.8 | ||
| 10 | 103/0.254 | 0.51 | 0.38 | 5.1±0.5 |
| 8 | 163/0.254 | 6.0±0.5 | ||
| 6 | 260/0.254 | 7.1±0.5 | ||
| 4 | 413/0.254 | 8.2±0.5 |
Electrical Properties of Mica Insulated Cable
- Conductor operating temperature: 90°C
- Ambient temperature: 30°C
Mica Insulated Wire Construction Parameters
| Noumber of Cores X Cross sectional Area | Conductor Class | Nominal Insulation Thickness | Nominal Inner Covering Thickness | Nominal Sheath Thickness | Overall Diameter | Weight |
|---|---|---|---|---|---|---|
| 5 cores | ||||||
| 5×1.5a | 2 | 0.7 | 0.4 | 1.8 | 13.5 | 218 |
| 5×2.5a | 2 | 0.7 | 0.4 | 1.8 | 14.5 | 281 |
| 5×4a | 2 | 0.7 | 0.6 | 1.8 | 16.9 | 378 |
| 5×10a | 2 | 0.7 | 0.6 | 1.8 | 20.2 | 700 |
| 5×16a | 2 | 0.7 | 0.8 | 1.8 | 24.3 | 1042 |
| 5×25a | 2 | 0.9 | 1.0 | 1.8 | 27.3 | 1594 |
| 5×35a | 2 | 0.9 | 1.0 | 1.8 | 30.9 | 2132 |
| 5×50a | 2 | 1.0 | 1.2 | 1.9 | 34.6 | 2855 |
| 5×70a | 2 | 1.1 | 1.2 | 2.1 | 38.4 | 4055 |
| 5×95a | 2 | 1.1 | 1.4 | 2.2 | 43.7 | 5503 |
| 5×120a | 2 | 1.2 | 1.4 | 2.4 | 46.9 | 6916 |
| 3 cores | ||||||
| 3×1.5a | 2 | 0.7 | 0.4 | 1.8 | 12.2 | 152 |
| 3×2.5a | 2 | 0.7 | 0.4 | 1.8 | 13.1 | 192 |
| 3×4a | 2 | 0.7 | 0.4 | 1.8 | 14.3 | 253 |
| 3×6a | 2 | 0.7 | 0.4 | 1.8 | 15.5 | 329 |
| 3×10a | 2 | 0.7 | 0.6 | 1.8 | 17.5 | 479 |
| 3×16a | 2 | 0.7 | 0.6 | 1.8 | 19.8 | 687 |
| 3×25a | 2 | 0.9 | 0.8 | 1.8 | 23.5 | 1033 |
| 3×35a | 2 | 0.9 | 0.8 | 1.8 | 26.0 | 1364 |
| 3×50a | 2 | 1.0 | 1.0 | 1.8 | 29.3 | 1798 |
| 3×70a | 2 | 1.1 | 1.2 | 1.9 | 33.8 | 2532 |
| 3×95a | 2 | 1.1 | 1.2 | 2.0 | 38.3 | 3421 |
| 3×120a | 2 | 1.2 | 1.2 | 2.1 | 42.4 | 4284 |
| 3×25b | 2 | 0.9 | 0.6 | 1.8 | 20.7 | 1001 |
| 3×35b | 2 | 0.9 | 0.8 | 1.8 | 23.3 | 1334 |
| 3×50b | 2 | 1.0 | 0.8 | 1.8 | 25.9 | 1757 |
| 3×70b | 2 | 1.1 | 1.0 | 1.9 | 29.8 | 2479 |
| 3×95b | 2 | 1.1 | 1.2 | 2.0 | 33.2 | 3351 |
| 3×120b | 2 | 1.2 | 1.2 | 2.1 | 36.0 | 4191 |
| 2 Cores | ||||||
| 2×1.5a | 2 | 0.7 | 0.4 | 1.8 | 11.6 | 139 |
| 2×2.5a | 2 | 0.7 | 0.4 | 1.8 | 12.4 | 167 |
| 2×4a | 2 | 0.7 | 0.4 | 1.8 | 13.5 | 211 |
| 2×6a | 2 | 0.7 | 0.4 | 1.8 | 14.6 | 265 |
| 2×10a | 2 | 0.7 | 0.6 | 1.8 | 16.5 | 370 |
| 2×16a | 2 | 0.7 | 0.6 | 1.8 | 18.6 | 515 |
| 2×25a | 2 | 0.9 | 0.8 | 1.8 | 22.0 | 756 |
| 2×35a | 2 | 0.9 | 0.8 | 1.8 | 24.3 | 983 |
| 2×50a | 2 | 1.0 | 1.0 | 1.8 | 27.4 | 1281 |
| 2×70a | 2 | 1.1 | 1.0 | 1.8 | 31.4 | 1771 |
| 2×95a | 2 | 1.1 | 1.2 | 1.9 | 35.4 | 2379 |
| 2×120a | 2 | 1.2 | 1.2 | 2.0 | 39.2 | 2971 |
| 2×25b | 2 | 0.9 | 0.6 | 1.8 | 18.1 | 695 |
| 2×35b | 2 | 0.9 | 0.6 | 1.8 | 19.9 | 917 |
| 2×50b | 2 | 1.0 | 0.8 | 1.8 | 22.6 | 1209 |
| 2×70b | 2 | 1.1 | 0.8 | 1.8 | 25.5 | 1684 |
| 2×95b | 2 | 1.1 | 1.0 | 1.9 | 28.2 | 2273 |
| 2×120b | 2 | 1.2 | 1.0 | 2.0 | 31.0 | 2844 |
| 4 cores | ||||||
| 4×1.5a | 2 | 0.7 | 0.4 | 1.8 | 13.2 | 183 |
| 4×2.5a | 2 | 0.7 | 0.4 | 1.8 | 14.2 | 234 |
| 4×4a | 2 | 0.7 | 0.4 | 1.8 | 15.5 | 313 |
| 4×6a | 2 | 0.7 | 0.6 | 1.8 | 16.9 | 412 |
| 4×10a | 2 | 0.7 | 0.6 | 1.8 | 19.2 | 608 |
| 4×16a | 2 | 0.7 | 0.6 | 1.8 | 21.7 | 881 |
| 4×25a | 2 | 0.9 | 0.8 | 1.8 | 25.8 | 1335 |
| 4×35a | 2 | 0.9 | 1.0 | 1.8 | 28.6 | 1773 |
| 4×50a | 2 | 1.0 | 1.0 | 1.8 | 32.3 | 2344 |
| 4×70a | 2 | 1.1 | 1.2 | 2.0 | 37.5 | 3329 |
| 4×95a | 2 | 1.1 | 1.2 | 2.1 | 42.3 | 4505 |
| 4×120a | 2 | 1.2 | 1.2 | 2.3 | 47.1 | 5667 |
| 4×25b | 2 | 0.9 | 0.8 | 1.8 | 23.3 | 1305 |
| 4×35b | 2 | 0.9 | 0.8 | 1.8 | 25.9 | 1740 |
| 4×50b | 2 | 1.0 | 1.0 | 1.8 | 29.4 | 2307 |
| 4×70b | 2 | 1.1 | 1.2 | 2.0 | 33.5 | 3271 |
| 4×95b | 2 | 1.1 | 1.2 | 2.1 | 36.9 | 4424 |
| 4×120b | 2 | 1.2 | 1.2 | 2.3 | 40.9 | 5565 |
Current Carrying Capacities of UL 5107 Wire
| Conductor cross sectional area | Method A | Method B | Method C | Method E | ||||
|---|---|---|---|---|---|---|---|---|
| two core cable, single phase a.c. or d.c. | three or four core cable threephase a.c. | two core cable singlephase a.c. or d.c. | three or four core cable three phase a.c. | two core cable single phase a.c. or d.c. | three or four core cable threephase a.c. | two core cable singlephase a.c. or d.c. | three or four core cable threephase a.c. | |
| 2.5 | 25 | 22 | 30 | 26 | 33 | 30 | 36 | 32 |
| 1.5 | 18.5 | 16.5 | 22 | 19.5 | 24 | 22 | 26 | 23 |
| 6 | 42 | 38 | 51 | 44 | 58 | 52 | 63 | 54 |
| 4 | 33 | 30 | 40 | 35 | 45 | 40 | 49 | 42 |
| 10 | 57 | 51 | 69 | 60 | 80 | 71 | 86 | 75 |
| 25 | 99 | 89 | 119 | 105 | 138 | 119 | 149 | 127 |
| 16 | 76 | 68 | 91 | 80 | 107 | 96 | 115 | 100 |
| 50 | 145 | 130 | 175 | 154 | 209 | 179 | 225 | 192 |
| 35 | 121 | 109 | 146 | 128 | 171 | 147 | 185 | 158 |
| 95 | 220 | 197 | 265 | 233 | 328 | 278 | 352 | 298 |
| 70 | 183 | 164 | 221 | 194 | 269 | 229 | 289 | 246 |
| 120 | 253 | 227 | 305 | 268 | 382 | 322 | 410 | 346 |
Voltage Drop of UL 5335 Mica Fiber Glass Wire
| Conductor crosssectional area | Two core cable | Two core cable | Three- or four core cable | ||||
|---|---|---|---|---|---|---|---|
| 2.5 | 19 | 19 | 16 | ||||
| 1.5 | 31 | 31 | 27 | ||||
| 6 | 7.9 | 7.9 | 6.8 | ||||
| 4 | 12 | 12 | 10 | ||||
| 16 | 2.9 | 2.9 | 2.5 | ||||
| 10 | 4.7 | 4.7 | 4.0 | ||||
| 25 | 1.85 | 1.85 | 0.160 | 1.90 | 1.60 | 0.140 | 1.65 |
| 50 | 0.98 | 0.99 | 0.155 | 1.00 | 0.86 | 0.135 | 0.87 |
| 35 | 1.35 | 1.35 | 0.155 | 1.35 | 1.15 | 0.135 | 1.15 |
| 70 | 0.67 | 0.67 | 0.150 | 0.69 | 0.59 | 0.130 | 0.60 |
| 120 | 0.39 | 0.40 | 0.145 | 0.42 | 0.34 | 0.130 | 0.37 |
| 95 | 0.49 | 0.50 | 0.150 | 0.52 | 0.43 | 0.130 | 0.45 |
Many stockists, distributors, stockholders, importers, suppliers, dealers, exporters purchase 450C 300V UL5128 Mica Fiberglass Wire from Bhuwal Insulation and supply in their own cities and countries with higher margins, so contact Mica Insulated Cable manufacturers in India and save cost
Physical And Thermal Properties of UL 5335/5107 MG Wire
- Maximum temperature range during operation: 90°C
- Maximum short circuit temperature (5 Seconds): 250°C
- Minimum bending radius
- circular copper conductors OD≤25mm: 4 × Overall Diameter
- circular copper conductors OD﹥25mm: 6 × Overall Diameter
- shaped copper conductors: 8 × Overall Diameter
Colour Code of UL 5107 Wire
- 2-core: Brown and blue.
- 3-core: Brown, black and grey.
- Alternatively, green-and-yellow, blue, brown.
- 4-core: Blue, brown black and grey.
- Alternatively, green-and-yellow, brown, black, grey.
- 5-core: Green-and-yellow, blue, brown black, grey.
- Sheath Colour: Black; other colours can be offered upon request.
Voltage Rating of Mica Insulated Cable
600/1000V
Packaging of Mica-Insulated Electric Cables
- Inner packing: wooden drum, plastic drum, paper drum
- Packing length:100 to 1000 Meter reeled in carton drum or according to customers' requirement
- The quantity in one ctn base on the type of cord and its length.
- Other packing requirement according to client's request
- Outer packing: wooden case, carton box
- Cables cut to length and shipped on nonreturnable reels
- Other packing for Cables is available as per customer demand
- Packing lengths of Cables: 100 Feet / roll, 100 meter / roll, 300feet / roll
- Outer packing: carton box, pull out box

















Table of Content