DLO Wire and Railway Locomotive Cables manufacturer in India
There are various cables and wires available in the market for different applications. Each one of them has its particular purpose and characteristic. Locomotive Cable is one of them. They are also known as DLO Cable or diesel Locomotive cable. They are rubber insulated and rubber jacketed flexible cables. They are mostly used in railway locomotives. Diesel is used by these 444 DLO Cable to drive generators to power electric motors that turn the wheelThese cables are used to efficiently transfer the power from generator to electric drive motor. 373 DLO Cable can work as a substitute for the welding cables that are frequently misused when there is a demand for flexible cable.
Diesel locomotive cable manufacturers recommend these cables as they have a high voltage rating of 2000V. The maximum continuous conductor temperature of these 535 DLO Cable in a dry location is 90 degrees C and in the wet location, it is 75 Degrees C. They display outstanding resistance to oil, alkalis, acids, and heat. Moreover, these 535 Mcm DLO Cable are also resistant to flames and abrasion. They are also used in drilling rigs, railroads, onshore and offshore applications, shipyards, power and control jumpers, and motor leads. Locomotive Cable is said to be more expensive and heavy when compared to copper cables. Welding cables and type W cables can be considered as alternatives however they have their own drawbacks. Out of these two types, type W can be considered a better alternative as they are durable and have a double layer of insulation that is thicker than the Diesel Locomotive Cable.
When compared with welded cables locomotive cable manufacturers in India recommend these DLO Wires because they display better resistance to corrosion when compared to the welded wires. They also carry dual ratings which the welded wire does not have. 777 DLO Cable produced by us is passed through various tests to conform to their properties. Our team of experts ensures that the raw material used in them is also procured from reliable sources and tested before using them. Railway Locomotive Cable is supplied by us throughout the world to be used in various industries at an affordable price. The product quality, prices and the timely delivery of these products has created trust among our customer and has made us one of the well known Railway Locomotive Cable manufacturers in India.
Manufacturer & supplier of DLO Cable with UL RHH/ UL RHW-2 and CSA RW90 rating
Locomotive Cable Specification Standard
| Number Of Cores | 2 / 3.5 / 4 |
| Power Voltage | 1100 Volt |
| Range | 6GA, 0GA, 2GA, 4GA, 18GA, 8GA, 14GA, 10GA, 15GA, 12GA, 16GA, 20GA |
| Temperature Range | 35 to 110 degree celsius |
| Colour | Black |
| Export To |
Tanzania, South Africa, Nigeria, Nepal, Saudi arabia, Nepal, Chile, Malaysia, Argentina, Indonesia, Srilanka, Kuwait, United States, Singapore, Sudan, MOZAMBIQUE, Saudi arabia, Poland, Oman, Oman, Qatar, Germany, Colombia, Dubai, Bhutan, Austria, United Arab Emirates, United kingdom, UNITED ARAB EMIRATES (UAE), Russia, Kuwait, Australia, Netherlands, Bangladesh, Cuba, Bahrain, Malawi, Brazil, MYANMAR, South Africa, MOROCCO, Belgium, Philippines, Qatar, Iraq, Italy, Bhutan, Sri lanka, Zambia, Egypt, Kenya, Israel |
| Conductor Material | Copper / Tinned Copper |
| Jacket | Extra hard usage black, oil and weather resistant CPE thermoset |
| Packing | pallet packing , carton packing, wooden / plastic reels |
| Insulation Material | Rubber / EPDM |
What is Diesel Locomotive Cable ?
Diesel Locomotive Cables has variety of applications in various industries. Extra flexible tinned copper conductor has a separator on sizes 4 AWG and larger. Insulated and jacketed with a EPR thermosetting insulation and jacket, It provides toughness along with good flexibility. These Cables Passes Flame Test with a continuous Temperature rating of 90°C.
Stranding and Standard of 373 DLO Cable
| Stranding | Tin coated copper conductor |
| Standard | RW-90 CSA, RHH/RHW-2 600V and 2000V, DLO 2KV, 1KV. |
Insulation and Voltage Of Diesel Locomotive Cables
| Insulation | Ethylene-propylene rubber (EPR) type EP, ICEA, UL, CSA, AAR RP-588, 90°C |
| Voltage | 600/2000 Volts |
535 DLO Cable Temperature Range
| Temperature Range | 90°C |
DLO Cable Price List
Description |
Locomotive Cables Price |
| 2awg 2000V EPR/CPE (DLO) Diesel Locomotive Cables Per Meters | US $2.90 |
| Irradiated cross-linked locomotive cables for vehicle Per Meters | US $0.48 |
| Diesel Locomotive Cables 2000V Per Meters | US $1.00 - $10.00 |
| flexible tinned copper conductor Diesel Locomotive Cable Per Meters | US $1.00 |
| Diesel Locomotive Cables 2KV, EPR/XL-CPE Per Meters | US $1.00 - $20.00 |
| RHH-RHW 4/0awg 600V-2000V EPR/CPE (DLO) Diesel Locomotive Cables Per Meters | US $10.20 |
| Single-core Flame Retardant Railway Cables for Locomotive 0.6/1KV Per Meters | US $5.00 - $105.00 |
| Rubber Power Cables 2KV Diesel Locomotive DLO Per Meters | US $1.00 - $10.00 |
| 2000V Diesel Locomotive Cables Per Meters | US $0.90 - $40.00 |
| electrical 1500V High Voltage Locomotive Cables flexible Per Meters | US $18.50 |
Locomotive Cables Structure Scheme

- Annealed tinned copper conductor
- EPR insulation
- CSP sheath

- Annealed tinned copper conductor
- Cross-linked polyolefin insulation
Dimensions of 777 DLO Cable
| Size | Stranded
TC Cond. |
Max OD | Amps
* |
Nominal (in) | Cables Weight | |
|---|---|---|---|---|---|---|
| AWG | Insulation | Jacket | LBs/MFT | |||
| 8 | 37 X 24 | 0.333 | 83 | 0.060 | 0.030 | 75 |
| 4 | 105 X 24 | 0.461 | 145 | 0.060 | 0.030 | 200 |
| 6 | 61 X 24 | 0.403 | 109 | 0.062 | 0.030 | 125 |
| 1 | 224 X 24 | 0.650 | 223 | 0.080 | 0.045 | 415 |
| 2 | 147 X 24 | 0.510 | 192 | 0.060 | 0.030 | 265 |
| 1/0 | 273 X 24 | 0.700 | 258 | 0.080 | 0.045 | 490 |
| 3/0 | 456 X 24 | 0.815 | 345 | 0.080 | 0.045 | 755 |
| 2/0 | 323 X 24 | 0.740 | 298 | 0.080 | 0.045 | 560 |
| 4/0 | 551 X 24 | 0.870 | 400 | 0.080 | 0.045 | 895 |
| 313 | 777 X 24 | 1.055 | 512 | 0.095 | 0.065 | 1255 |
| 262 | 646 X 24 | 0.990 | 458 | 0.095 | 0.065 | 1085 |
| 373 | 925 X 24 | 1.125 | 574 | 0.095 | 0.065 | 1485 |
| 535 | 1332 X 24 | 1.305 | 723 | 0.110 | 0.065 | 2090 |
| 646 | 1591 X 24 | 1.410 | 814 | 0.110 | 0.065 | 2470 |
| 444 | 1110 X 24 | 1.205 | 642 | 0.095 | 0.065 | 1745 |
| 777 | 1924 X 24 | 1.098 | 917 | 0.109 | 0.065 | 2910 |
| 1111 | 2745 X 24 | 1.800 | 1143 | 0.125 | 0.095 | 4150 |
| 929 | 2318 X 24 | 1.610 | 1025 | 0.120 | 0.065 | 3417 |
Manufacturer & exporter of EPR insulated 777/ 444/ 373 DLO Cable in 14 AWG to 1111 kcmil conductor sizes
Construction of DLO Wire
- Conductor: bunch-stranded tinned ASTM Class 1 copper, Rope-lay
- Voltage Ratings: RHH/RHW-2 600 V / 2,000 V
- Separator: Paper (conductor) / Mesh (insulation)
- Insulation & Jacket: halogen-free EPDM compound, Insulated with low-smoke / Jacketed with CPE compound
535 DLO Cables Resistance Properties
- Crushing Force
- Resistant To Abrasion
- Flame
- Sunlight
- Impact
- Extreme Temperatures
- Oil
- 60°c (140°f) Oil Resistant Temperature Rating
- Water
Temperature Range of Railway Locomotive Cable
| Temperature Range | Dry: -40°C (-40°F) to 90°C (194°F) / Wet: 90°C (194°F) |
Diesel Locomotive Cables Industry Approvals
- UL Listed RHH
- MSHA FT5
- UL FT1, FT2, FT4 / IEEE 1202, VW-1
- IAW UL 1650, 44, 2556
- UL Low-Smoke ST-1
- ASTM B49, B33, B172, B174
Dimensions of DLO Cables
| AWG Size | Stranding Gauges | Conductor Stranding | Wall Thickness
(Nominal) |
Outside Dia
(Nominal) |
Cables Weight
(per 1,000') |
Ampacity* | |||
|---|---|---|---|---|---|---|---|---|---|
| in | mm | in | mm | lbs | kg | ||||
| #2 | 24 GA | 150 | .030 | .760 | .489 | 12.42 | 248 | 112 | 190 A |
| 1 / 0 | 24 GA | 275 | .045 | 1.14 | .642 | 16.31 | 480 | 218 | 260 A |
| #1 | 24 GA | 225 | .045 | 1.14 | .583 | 14.81 | 428 | 194 | 220 A |
| 2 / 0 | 24 GA | 325 | .045 | 1.14 | .681 | 17.30 | 558 | 253 | 300 A |
| 4 / 0 | 24 GA | 550 | .045 | 1.14 | .815 | 20.70 | 872 | 396 | 405 A |
| 3 / 0 | 24 GA | 450 | .045 | 1.14 | .781 | 19.84 | 742 | 337 | 350 A |
| 262 MCM | 24 GA | 650 | .065 | 1.65 | .921 | 23.39 | 1,068 | 484 | 471 A |
| 373 MCM | 26 GA | 925 | .065 | 1.65 | 1.055 | 26.80 | 1,462 | 663 | 590 A |
| 535 MCM | 28 GA | 1,325 | .065 | 1.65 | 1.244 | 31.60 | 2,018 | 915 | 731 A |
| 313 MCM | 24 GA | 775 | .065 | 1.65 | .984 | 24.99 | 1,258 | 571 | 511 A |
| 444 MCM | 27 GA | 1,100 | .065 | 1.65 | 1.138 | 28.91 | 1,726 | 783 | 656 A |
777 DLO Cables Stock & Packaging
Stock
- Coils/Assemblies at 25’, 50’, 100’, and 250’
- Reels at 500’, 1,000’, and 2,500’
- Custom lengths available upon request
Packaging
- Reeled, palletized, and strech-wrapped
Technical Specification Table of 535 Mcm Single Core Dlo Cables
| Conductor Size | Number of Strands | Size of Each Strand | Insulation Thickness | Jacket Thickness | Maximum Overall Diameter | Approximate Total Weight |
| AWG or kcmil | AWG | mil | mil | in | lb/kft | |
| 14 | 19 | 27 | 45 | 25 | 0.22 | 33 |
| 12 | 19 | 25 | 45 | 30 | 0.25 | 46 |
| 10 | 27 | 24 | 45 | 30 | 0.28 | 65 |
| 8 | 37 | 24 | 60 | 30 | 0.33 | 91 |
| 6 | 63 | 24 | 60 | 30 | 0.39 | 136 |
| 4 | 105 | 24 | 60 | 30 | 0.45 | 201 |
| 2 | 154 | 24 | 60 | 30 | 0.51 | 274 |
| 1 | 224 | 24 | 80 | 45 | 0.65 | 419 |
| 1/0 | 273 | 24 | 80 | 45 | 0.69 | 492 |
| 2/0 | 323 | 24 | 80 | 45 | 0.74 | 575 |
| 3/0 | 426 | 24 | 80 | 45 | 0.83 | 770 |
| 4/0 | 551 | 24 | 80 | 45 | 0.89 | 884 |
| 263 | 646 | 24 | 95 | 65 | 1.01 | 1114 |
| 313 | 779 | 24 | 95 | 65 | 1.08 | 1309 |
| 374 | 931 | 24 | 95 | 65 | 1.14 | 1528 |
| 444 | 1110 | 24 | 95 | 65 | 1.22 | 1785 |
| 535 | 1332 | 24 | 110 | 65 | 1.33 | 2140 |
| 646 | 1591 | 24 | 110 | 65 | 1.42 | 2546 |
| 778 | 1952 | 24 | 110 | 65 | 1.53 | 3017 |
| 929 | 2318 | 24 | 110 | 65 | 1.64 | 3529 |
| 1111 | 2745 | 24 | 125 | 95 | 1.85 | 4291 |
535 Mcm DLO Cables Applications
- Portable Motor And Power Leads For Diesel Vehicles
- Railroad And Transit Cars
- Bulldozers
- Drilling Rigs
- Storage Batteries
- Electric earth-moving equipment
- Shipyard machinery and equipment
- Supply leads for arc welders
- Drilling rigs, both on-shore and off-shore
- Railroad and transit cars
- earth moving equipment
- drilling rigs
- marine shipboard cable
- Battery Cable
- Arc Welding Cable
- control panel power distribution
- Power and control jumper cables
DLO Cables Max Operating Range
| Max Operating Range | 90 C |
Diesel Locomotive Cables Construction and Data Sheet
- Size: 14 AWG
- Conductor Strand: 19/27
- Insulation Thickness: 0.047 inches
- Jacket Thickness: 0.51 mm / 0.020 inches
- Outside Diameter: 0.20 inches
- Weight: 0.025 lbs per ft
| 1X Part # | DLO Sizes | Strands | Insul. (in) | Jacket (in) | O.D. (in) | LBS/MFT | Amps |
| DLO-14 | 14 | 19/27 | 0.045 | 0.015 | 0.218 | 30 | 35 |
| DLO-10 | 10 | 27/24 | 0.045 | 0.015 | 0.266 | 67 | 55 |
| DLO-12 | 12 | 19/25 | 0.045 | 0.015 | 0.240 | 46 | 40 |
| DLO-8 | 8 | 37/.0211 | 0.065 | 0.030 | 0.3363 | 105 | 80 |
| DLO-4 | 4 | 105/24 | 0.065 | 0.030 | 0.4503 | 205 | 140 |
| DLO-6 | 6 | 61/24 | 0.065 | 0.030 | 0.3807 | 146 | 105 |
| DLO-2 | 2 | 161/24 | 0.065 | 0.045 | 0.5020 | 293 | 190 |
| DLO-1/0 | 1/0 | 266/24 | 0.085 | 0.045 | 0.6900 | 525 | 260 |
| DLO-2/0 | 2/0 | 342/24 | 0.085 | 0.045 | 0.7300 | 660 | 300 |
| DLO-1 | 1 | 210/24 | 0.085 | 0.045 | 0.6500 | 392 | 220 |
| DLO-3/0 | 3/0 | 418/24 | 0.085 | 0.045 | 0.8100 | 760 | 350 |
| DLO-262.6 | 262.6 | 646/24 | 0.100 | 0.065 | 0.9200 | 1130 | 467 |
| DLO-4/0 | 4/0 | 551/24 | 0.080 | 0.045 | 0.8700 | 930 | 405 |
| DLO-313.1 | 313.1 | 779/24 | 0.100 | 0.065 | 0.9680 | 1400 | 518 |
| DLO-373.7 | 373.7 | 931/24 | 0.100 | 0.065 | 1.0650 | 1545 | 588 |
| DLO-444.4 | 444.4 | 1102/24 | 0.100 | 0.065 | 1.1320 | 1820 | 649 |
| DLO-535.3 | 535.3 | 1330/24 | 0.125 | 0.065 | 1.2400 | 2023 | 725 |
| DLO-646.4 | 646.4 | 1590/24 | 0.125 | 0.065 | 1.3590 | 2560 | 814 |
| DLO-777.7 | 777.7 | 1924/24 | 0.125 | 0.065 | 1.3820 | 3050 | 900 |
| DLO-929.2 | 929.2 | 2299/24 | 0.120 | 0.065 | 1.6700 | 3123 | 1014 |
| DLO-1111 | 1111.0 | 2745/24 | 0.140 | 0.065 | 1.8400 | 4354 | 1115 |
Various Sizes and Specification of Locomotive Cables
12 AWG Diesel Locomotive Cables 2KV
- DLO Size: 12 AWG DLO Cables
- Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
- 12 AWG DLO Cables Ampacity — Amperage: 40 Amps
- Weight per 1000 Feet: 46 lbs.
- 12 AWG DLO Cables Dimensions, Outside Diameter O.D. — .240 In.
- Bend Radius Fixed (x4): .960 In.
- Bend Radius Flexible (x6): 1.44 In.
10 AWG Diesel Locomotive Cables 2KV
- DLO Size: 10 AWG DLO Cables
- Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
- 10 AWG DLO Cables Ampacity — Amperage: 55 Amps
- Weight per 1000 Feet: 67 lbs.
- 10 AWG DLO Cables Dimensions, Outside Diameter O.D. — .266 In.
- Bend Radius Fixed (x4): 1.064 In.
- Bend Radius Flexible (x6): 1.596 In.
8 AWG Diesel Locomotive Cables 2KV
- DLO Size: 8 AWG DLO Cables
- Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
- 8 AWG DLO Cables Ampacity — Amperage: 80 Amps
- Weight per 1000 Feet: 105 lbs.
- 8 AWG DLO Cables Dimensions, Outside Diameter O.D. — .3363 In.
- Bend Radius Fixed (x4): 1.3452 In.
- Bend Radius Flexible (x6): 2.0178 In.
535 Mcm DLO Cable with flex lugs supplier & exporter in India as per UL 44 & UL 1581 Standards
Manufacturer of Diesel Locomotive Cables and Supplied in Below Industries

Mining Industry
Epr Insulation CPE Sheathed Diesel Locomotive Cables
Bhutan, Germany, Bangladesh, Malaysia, Russia, Egypt, Dubai, Bahrain, United States, Netherlands, Malawi, Argentina

Automobiles Industry
24p Cables Locomotive for Crane Hoist
Austria, Qatar, Tanzania, United Arab Emirates, Bhutan, Chile, Kuwait, South Africa, Srilanka, Colombia, Indonesia, Kenya

Aerospace Industry
Flexible Copper Conductor 2kv Locomotive Dlo Cables
Singapore, Saudi arabia, MOROCCO, Sudan, MYANMAR, MOZAMBIQUE, Oman, Oman, Qatar, Nepal, Israel, Nigeria, Kuwait, Belgium
Feature of 444 DLO Cables
- 90°C temperature rating
- Excellent impact and abrasion resistance
- Resists oils, acids, alkalies, heat and flame
- Flexible tinned copper stranding
600/ 2000 Volts Diesel Locomotive Cable manufacturer in Mumbai, check ampacity, sizes and price in Mumbai
Technical Specifications of 777 DLO Cables
| Diameter size | Bending radius |
| D≤10mm | ≤2D |
| 20mm≤D>10mm | ≤4D |
| D>20mm | ≤6D |
Sizes of Diesel Locomotive Cables
| Cross Section (mm2) | Approximate Overall Diameter (mm) | Current Rating | |
| Single Phase (Amps) | Three Phase (Amps) | ||
| 1.5 | 2.9 | 17.5 | 15.5 |
| 2.5 | 3.53 | 24 | 21 |
| 4 | 4.4 | 32 | 28 |
| 6 | 4.68 | 41 | 36 |
| 10 | 5.98 | 57 | 50 |
| 16 | 6.95 | 76 | 68 |
| 25 | 8.7 | 101 | 89 |
| 35 | 10.08 | 125 | 110 |
| 50 | 11.8 | 151 | 134 |
| 70 | 13.5 | 192 | 171 |
| 95 | 15.7 | 232 | 207 |
| 120 | 17.4 | 296 | 239 |
| 150 | 19.3 | 300 | 262 |
| 185 | 21.5 | 341 | 296 |
| 240 | 24.6 | 400 | 346 |
| 300 | 27.9 | 458 | 394 |
| 400 | 30.8 | 546 | 467 |
| 500 | 33.8 | 626 | 533 |
| 630 | 37.6 | 720 | 611 |
| International standard wire size Chart (IEC 60228) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 0.75 mm² | 4 mm² | 0.5 mm² | 1 mm² | 2.5 mm² | 1.5 mm² | ||||
| 70 mm² | 6 mm² | 25 mm² | 185 mm² | 35 mm² | 400 mm² | ||||
| 95 mm² | 1000 mm² | 10 mm² | 800 mm² | 150 mm² | 50 mm² | ||||
| 300 mm² | 120 mm² | 500 mm² | 16 mm² | 630 mm² | 240 mm² | ||||
DLO Diesel Locomotive Cables Dimensions
| Cond. Size | Cond. Strand | Nom. Insul. Thickness (Inches) | Nom. O. D. (Inches) | AMPS* | Ship. Weight (lbs/mft) |
|---|---|---|---|---|---|
| 2 | 147 x 0.0201 | 0.06 | 0.52 | 184 | 295 |
| 36526 | 275 x 0.0201 | 0.08 | 0.69 | 268 | 515 |
| 36557 | 324 x 0.0201 | 0.08 | 0.73 | 298 | 580 |
| 36586 | 448 x 0.0201 | 0.08 | 0.81 | 342 | 770 |
| 36617 | 551 x 0.0201 | 0.08 | 0.87 | 415 | 930 |
| 262 | 646 x 0.0201 | 0.095 | 1 | 461 | 1130 |
| 313 | 779 x 0.0201 | 0.095 | 1.06 | 514 | 1295 |
| 373 | 925 x 0.0201 | 0.095 | 1.1 | 575 | 1545 |
| 444 | 1110 x 0.0202 | 0.095 | 1.23 | 641 | 1820 |
| 535 | 1332 x 0.0203 | 0.12 | 1.34 | 720 | 2195 |
| 646 | 1591 x 0.0204 | 0.11 | 1.45 | 811 | 2560 |
| 777 | 1924 x 0.0205 | 0.11 | 1.5 | 911 | 3050 |
| 1111 | 2745 x 0.0206 | 0.125 | 1.84 | 1139 | 4354 |
Various Types of Locomotive Cable

















Table of Content